- Conducted emissions
– DC 9 kHz -200 MHz
– AC 150 kHz – 30 MHz
– Ethernet
- Radiated emissions
– 9 kHz – 40 GHz
- Harmonic current emissions
- Voltage fluctuation and flicker
- Spurious emissions
- Many different conducted radio tests (e.g. LTE, 5G, Wlan ,BT)
- Surge 1.2/50 us (8/20 us) up to 7 kV
- EFT/BURST up to 7 kV
- Power frequency magnetic field immunity
- Impulse magnetic field immunity
- ESD up to 30 kV
- Voltage dips and short interruptions
- Radiated field immunity test
80 MHz – 6 GHz 10 V/m
- Proximity fields from wireless communication equipment
- CM RF conducted immunity test, 10 Vrms
- IEEE-299
- Tailored Shielding effectiveness tests (e.g. enclosures, gaskets, windows, meshes, ventilation panels etc.)
- Up to 40 GHz
- Can be done in-situ
We provide electromagnetic compatibility solutions including design reviews, hands-on EMI troubleshooting, pre-compliance hardware evaluations.
- EMC requirement analysis to the customer requirements.
- EMC technical guidance to system and equipment design.
- Analysis of EMC performance and installation design of the system and to identify areas of risk.
- Support engineering and test efforts in resolving EMC problems.
Our accredited and pre-compliance EMC Testing is carried out according to these standards, specifications and directives:
RED Radio Equipment Directive (2014/53/EU) establishes a regulatory framework for placing radio equipment on the market
EMC Directive 2014/30/EU regulates electromagnetic interference of electrical and electronic equipment.
- 3GPP TS 38.113 Release 16 Base Station (BS) Electro Magnetic Compatibility (EMC)
-
3GPP TS 38 113 Release 15
-
3GPP TS 37 113 Release 15
-
3GPP TS 37 114 Release 15
-
3GPP TS 38 124 Release 15
- EN 55011 Industrial, scientific and medical equipment – RF disturbance characteristics – Limits and methods of measurement.
- EN 55016 Specification for radio disturbance and immunity measuring apparatus and methods
- EN 55025 Vehicles, boats and internal combustion engines – Radio disturbance characteristics
- EN 55032 Electromagnetic compatibility of multimedia equipment – Emission requirements
- EN 61000-3-2 Limits for harmonic current emissions (equipment input current =16 A per phase)
- EN 610000-3-3 voltage fluctuations and flicker in public low-voltage supply systems, for equipment with rated current <= 16 A
- EN 61000-4-2 Testing and measurement techniques – Section 2: Electrostatic discharge (ESD) immunity test
- EN 61000-4-3 Testing and measurement techniques – Section 3: Radiated, radio-frequency, electromagnetic field immunity test.
- EN 61000-4-4 Testing and measurement techniques – Section 4: Electrical fast transient/burst immunity test
- EN 61000-4-5 Testing and measurement techniques – Section 5: Surge immunity test
- EN 61000-4-6 Testing and measurement techniques – Section 6: Immunity to conducted disturbances, induced by radio-freq. fields
- EN 61000-4-8 Testing and measurement techniques Section 8: Power frequency magnetic field immunity test.
- EN 61000-4-9 Testing and measurement techniques Section 9: Pulse magnetic field immunity test
- EN 61000-4-11Testing and measurement techniques – Section 11: Voltage dips, short interruptions and voltage variations.
- EN 61000-6-1 Generic standards – Immunity standard for residential, commercial and light-industrial environments
- EN 61000-6-2 Generic standards – Immunity standard for industrial environments
- EN 61000-6-3 Generic standards – Emission standard for equipment in residential environments
- EN 61000-6-4 Generic standards – Emission standard for industrial environments.
- ETSI EN 301 489-1 standard for radio equipment and services; Part 1: Common technical requirements; Harmonised Standard for EMC
- ETSI EN 301 908-1 IMT cellular networks; Harmonised Standard for access to radio spectrum; Part 1: Introduction and common requirements
- EN 300 328 Wideband transmission systems;. Data transmission equipment operating in the 2,4 GHz ISM band
- EN 300 440 Short Range Devices (SRD);. Radio equipment to be used in the 1 GHz to 40 GHz frequency range
- EN 301 893 5 GHz RLAN; Harmonised Standard covering the essential requirements of article 3.2 of Directive 2014/53/EU
- FCC CFR 47 part15B RADIO FREQUENCY DEVICES · Subpart A – General (§§ 15.1 – 15.38) · Subpart B – Unintentional Radiators (§§ 15.101 – 15.123)
- FCC CFR part 15C RADIO FREQUENCY DEVICES … Subpart C – Intentional Radiators (§§ 15.201 –
- 15.258)
- IEC 60601-1-2 Medical electrical equipment – Part 1-2: General requirements for basic safety and essential performance – Collateral Standard: Electromagnetic disturbances – Requirements and tests
We are also able to do custom measurements, the standards above are examples of what we can provide.